Level 1 Hotline® Alternative

Considering a purchase of a Level 1 Hotline® blood/fluid warmer?

Discover why hundreds of hospitals converted from Level 1 Hotline® to the Warrior line of next-generation blood/fluid warmers:

With the Warrior line of Warmers, you can:

WARRIOR AC
LEVEL 1 HOTLINE®
Max Delivery Rate at 4°C input [1]
290 ml/min
83 ml/min (5 liter/hour)
Max Delivery Rate at 20°C input [1]
500 ml/min
83 ml/min (5 liter/hour)
Warming Speed
Within seconds
4 minutes
Warming with Intense Push/Pull Resuscitation Techniques [2]
Performance validated
See note [3]
Priming Volume
19 ml
20 ml
Set Temperature
38°C, with tolerances
37°C, with tolerances
The Disposable Unit Can Be Easily Disconnected from One Device and Reconnected to the Next Device [4]
Yes, within seconds
N/A
Battery Option
Yes
No
Aluminum Free
Yes
Yes
Dry / Wet Warming Technology
Dry warming technology
Wet warming technology
Service Requirements
Inspection in 5 years
Monthly / yearly disinfection

Notes:

[1] The term “Max Delivery Rate” means “the maximum flow rate in which target temperature – typically 38°C — will be reached”.
[2] E.g. hand pump, LifeFlow-like devices, etc.
[3] Based on manufacturer published data, the device cannot warm blood or near freeze fluids in flow rates exceeding 83ml/min. Therefore, high flows generated by push-pull resuscitation techniques may be difficult for the device to handle. It is recommended to consult with the manufacturer.
[4] To facilitate warming during interfacility and intra-facility transports.

DISCLAIMERS: The table above compares selected product attributes of Hotline® (a registered trademark of Smiths Medical, which is part of the global technology business Smiths Group plc) with those of the Warrior AC configuration (manufactured by Quality In Flow, or QinFlow). Quality in Flow is not affiliated with Smith Medical. The benchmarking is based on publicly available information and the respective device’s Instructions for Use (IFU) / User Manual, where applicable. The Hotline® IFU / User Manual used for this study may not be the most updated version. Further, the IFUs / User Manuals used for this study may be changed by the manufacturer as the products evolves; QinFlow may not know about such updates and in any event does not undertake to update the information in the table upon such changes. Unless stated differently, the benchmark information was commissioned by QinFlow alone and not all data points were independently verified. Smith Medical was not part of this benchmark study. Use of the Warrior is subject to QinFlow’s terms of use. This benchmark study does not intend to cover all the differences between the devices. QinFlow does not guarantee that Hotline® will achieve the results or perform as mentioned in the benchmark study. QinFlow only warrants the information published in its IFUs (performance data points above are in accordance with the CE marks of each Warrior configuration; for FDA-cleared IFU, where applicable, contact QinFlow). Please contact Smith Medical Technologies for clarifications.